To delete an existing printer, select the printer and click the Delete button on the toolbar. The printer is removed from the printer list. Click Apply to save the changes and restart the printer daemon.
To set the default printer, select the printer from the printer list and
click the Default button on the toolbar. The
default printer icon
appears in the Default column of the default printer in
the list.
After adding the printer(s), the settings can be edited by selecting the printer from the printer list and clicking the Edit button. The tabbed window shown in Figure 27-12 is displayed. The window contains the current values for the selected printer. Make any necessary changes, and click OK. Click Apply in the main Printer Configuration Tool window to save the changes and restart the printer daemon.
To rename a printer or change its short description, change the value in the Queue name tab. Click OK to return to the main window. The name of the printer should change in the printer list. Click Apply to save the change and restart the printer daemon.
The Queue type click OK to return to the main window. Click Apply to save the changes and restart the printer daemon.
Depending on which queue type is chosen, different options are displayed. Refer to the appropriate section on adding a printer for a description of the options.
The Printer driver tab shows which print driver is currently being used. If it is changed, click OK to return to the main window. Click Apply to save the change and restart the printer daemon.
The Driver Options tab displays advanced printer options. Options vary for each print driver. Common options include:
Send Form-Feed (FF) should be selected if the last page of the print job is not ejected from the printer (for example, the form feed light flashes). If this does not work, try selecting Send End-of-Transmission (EOT) instead. Some printers require both Send Form-Feed (FF) and Send End-of-Transmission (EOT) to eject the last page. This option is only available with the LPRng printing system.
Send End-of-Transmission (EOT) should be selected if sending a form-feed does not work. Refer to Send Form-Feed (FF) above. This option is only available with the LPRng printing system.
Assume Unknown Data is Text assumes that any data that it can not recognize is text and attempts to print it as text. If this option is selected along with the Convert Text to Postscript option, the print driver assumes the unknown data is text and then converts it to PostScript. This option is only available with the LPRng printing system.
Prerender Postscript PostScript fonts so that they are printed correctly.
Extra time is required to perform this action. Do not choose it unless problems printing the correct fonts exist.
Also select this option if the printer can not handle PostScript level 3. This option converts it to PostScript level 1.
GhostScript pre-filtering — allows you to select No pre-filtering, Convert to PS level 1, or Convert to PS level 2 in case the printer can not handle certain PostScript levels. This option is only available if the PostScript driver is used with the CUPS printing system.
Convert Text to Postscript used, this is not an option because text is always converted to PostScript.
Page Size allows the paper size to be selected. The options include US Letter, US Legal, A3, and A4.
Effective Filter Locale defaults to C. If Japanese characters are being printed, select ja_JP. Otherwise, accept the default of C.
Media Source defaults to Printer default. Change this option to use paper from a different tray.
To modify the driver options, click OK to return to the main window. Click Apply to save the change and restart the printer daemon.